Seismic Anchors to Concrete
Single Expansion Anchor
OPM Page 7a.1
Detail 7a.1-1

8e4ce5ca84164c079631dc33aeb47f57.png?sfvrsn=7c7600b6_0)
Notes:
- FP capacities above are ASD capacities increased by 1.2 including Ω0 per ASCE 7-10 § 12.4.3. For braces at a 0° angle, the FP capacities listed are the allowable shear capacities of the anchors in concrete divided by Ω0.
- These values apply only when using Unistrut brand products with the anchors listed on OPM page 1h.3.
Two Expansion Anchors
OPM Page 7a.1
Detail 7a.1-2

.png?sfvrsn=540a9bb0_0)
Notes:
- FP capacities above are ASD capacities increased by 1.2 including Ω0 per ASCE 7-10 § 12.4.3. For braces at a 0° angle, the FP capacities listed are the allowable shear capacities of the anchors in concrete divided by Ω0.
- These values apply only when using Unistrut brand products with the anchors listed on OPM page 1h.3.
Single Expansion Anchor
Vertical Only
OPM Page 7a.2
Detail 7a.2-1

.png?sfvrsn=fd9e5d05_0)
Notes:
- Tension capacities with seismic load effect above are ASD capacities increased by 1.2 including Ω0 per ASCE 7-10 § 12.4.3.
- These values apply only when using Unistrut brand products with the anchors listed on OPM page 1h.3.
Two Expansion Anchors
Vertical Only
OPM Page 7b.2
Detail 7a.2-2

.png?sfvrsn=514a61e8_0)
Notes:
- Tension capacities with seismic load effect above are ASD capacities increased by 1.2 including Ω0 per ASCE 7-10 § 12.4.3.
- These values apply only when using Unistrut brand products with the anchors listed on OPM page 1h.3.